Rated Electric Fuse Cutout / Composite Fuse Cutout 10kv

Place of Origin CN;SHAAN XI
Brand Name TID POWER
Certification ISO9001
Model Number HRW
Minimum Order Quantity 100.0 Piece/Pieces
Price Negotiate
Packaging Details Suitable packing for export: Cartons+Wooden cases+Pallets+Wrapping Film
Payment Terms L/C , T/T

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Color Grey Or Customized Rated Short-time Power Frequency Withstand Voltage 10kV
Parts Base,Post Insulators,Conductive Part,Institutional Part Product Name Fuse Cut Out
Material Composite Polymer
High Light

50ka Rated Cutout Electric Fuse

,

Cutout Electric Fuse Short Time

,

Withstand Current Porcelain Fuse Cutout

Product Description

Rated Electric Fuse Cutout / Composite Fuse Cutout 10kv:

 

Products:

Cut-out fuse and Load-off cut-out fuse, are suitable for power transformer and line short circuit, over-load prote
-ction as well asbreaking and making load current using in power system which rated frequency 50Hz, rated voltage 35kV or less, installing high voltage side of power distribution transformer or distributing main line. They are one kind ideal outdoor protector.

Features:

Cut-out fuse is made of insulating base, live and fixed contact and fuse tube. Fixed contact installed on both sides of insulating base, and live contact installed on both sides offuse tube, which is made of inner arc-quenching tube and out bakelite paper tube or epoxy-glass fiber fabric tube. Load-off cutout fuse is used for breaking& making load current with adding spring auxiliary contacts and arc-quenching cover. When cutoutfuse under nomal working condition, fuse tube forms close location with help of tight for fuse link. When any faults come out in system, fault current make fuse link melt promptly, and form arcing, arc-quenching tube heated by arc,decompose lot of gas, produce great pressure inside of tu be, and blow vertically in high strength, the electric arc would be lengthened and quenched quickly. After melting of fuse link, fixed contact below turn down due to lost of ten sion, itmakes locking mechanism to release fuse tube to fall down,it forms obvious breaking off location. When necessary to pul-off load, unhinge contact with insulating link, live and fixed contacts are still connected, to pull contacts continuous with insulating link, auxiliary switch also would be apart, it make electric arc between auxiliary switches, arc would be lengthened in narrow slot of arc-quenching cover, which produce gas at same time, to quench the arc when current over zero.

 

Technical Parameters of Rated Electric Fuse Cutout / Composite Fuse Cutout 10kv:

Product Model HRW3-10/100 HRW3-10/200
Rated Voltage(kV) 10 10
Rated Current (A) 100 100
Breaking Current capacity (VA) Up limit 100 200
Down Limit 10 20
P.F.Dry Withstand Voltage (kV) 42 42
P.F.Wet Withstand Voltage (kV) 34 34
 
Rated Electric Fuse Cutout / Composite Fuse Cutout 10kv
TID POWER Drop Fuse Cutout
  • Brand Name: TID POWER
  • Model Number: TID-HRW
  • Place of Origin: CN;SHAAN XI
  • Rated Voltage: 10kV
  • Color: Grey Or Customized

Support and Services:

Technical Support and Service for Fuse Cut Out

At Fuse Cut Out, we are committed to providing the highest level of technical support and service. We understand the importance of providing our customers with a reliable and secure product that meets their needs. That's why we have a team of highly experienced and knowledgeable professionals ready to help whenever you need it.

Our technical support and service team is available 24 hours a day, 7 days a week, and 365 days a year. We provide on-site and telephone support, as well as online resources such as FAQs and product manuals. Our team can also assist with software installation, troubleshooting, and maintenance.

For more information about our technical support and service, please visit our website or contact us directly. We look forward to hearing from you.

Packing and Shipping:

The Fuse Cut Out product will be packaged in a cardboard box with bubble wrap and foam inserts to protect the product from damage during transit. All of the necessary installation accessories will be included with the product.

The Fuse Cut Out product will be shipped using standard shipping services such as UPS, FedEx, or USPS. The package will be tracked and insured to ensure it arrives at its destination in a timely and secure manner.

 

Rated Electric Fuse Cutout / Composite Fuse Cutout 10kv 0