Cynthia ZaneEasy to communicate and very professional. Good packaging.
-
Gus VerduzcoGreat company and team. The product quality is good, and the after-sales team is very responsible
-
Edson Polli juniorexcelente brillo, ahora a ver funciónamiento
-
Edson Polli juniorexcelente brillo, ahora a ver funciónamiento
Customizable Thickness Epoxy Fiberglass Rod IEC61109 G10 Fiberglass Rod
Place of Origin | CN;SHAAN XI |
---|---|
Brand Name | TID POWER |
Certification | ISO9001:2008 |
Model Number | TECR |
Minimum Order Quantity | 100 Meter/Meters |
Price | Negotiate |
Packaging Details | suitable packing for export,; 1.Inside packing: a plastic bag or woven belt 2.Outside packing: carton box and pallet. 3.According customer requirement. |
Payment Terms | L/C ,T/T |
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xDurability | High | Dimensions | 4mm-130mm |
---|---|---|---|
Application | Composite Insulator/fuse Cut Out | Heat Resistance | High |
Color | Green Or Brown | Impact Resistance | High |
Length | Customized | Material | Epoxy Resin ,Fiberglass,Firming Agent |
Highlight | Customizable Thickness Epoxy Fiberglass Rod,Epoxy Fiberglass Rod IEC61109,IEC61109 G10 Fiberglass Rod |
Customizable Thickness fiberglass rods that conforms to IEC61109 Standard
Insulating Solid Rod is made of ECR glass reinforced epoxy resin.We use continuous pultrusion procss .The products fullfill The standard of IEC61109, IEC 60855 and GB13398.
Note:
1. Color: light green , brown or customized colors.
2. Length: according to Customer requirement.
3. We offer customized products,including the new size, New surface treatment, Jointing the fitting, screw or mechanical to other shapes.
Technical Parameters of Customizable Thickness fiberglass rods that conforms to IEC61109 Standard:
No. | Technical specification | Unit | value |
1 | Density(20℃±2℃) | g/cm3 | ≥2.2 |
2 | Water absorption rate (20℃±2℃,24h) | % | ≤0.05 |
3 | Tensile strength | Mpa | ≥1200 |
4 | Bending strength | Mpa | ≥960 |
5 | Dye penetrated test | Min | ≥15 |
6 | Water diffusion test (1%NaCl, 100h 12kv/1min) | mA | ≤0.1 |
7 | Shearing strength along laminas | Mpa | ≥50 |
8 | Volume resistivity (140℃,96h) | Ω.M | ≥1010 |
9 | DC withstand voltage (10mm) | Kv | ≥50 |
10 | Lighting impulsed withstand voltage (100kv,10mm) | Times | ≥5 |
11 | Bending strength at heating conditions | Mpa/150℃ | ≥350 |
12 | Torsion strength | Mpa | ≥800 |
13 | Stress corrosion (1mol/1HNO3,at 67%stress) | h | 96 |
Size of Customizable Thickness fiberglass rods that conforms to IEC61109 Standard:
Products Code | D(mm) | L (mm) | Weight (kg) | Products Code | D(mm) | L (mm) | Weight (kg) |
TECR00400 | Φ4 | 1000 | 0.028 | TECR03600 | φ36 | 1000 | 2.20 |
TECR00450 | Φ4.5 | 1000 | 0.035 | TECR03800 | φ38 | 1000 | 2.46 |
TECR00500 | Φ5 | 1000 | 0.05 | TECR04000 | φ40 | 1000 | 2.70 |
TECR00550 | Φ5.5 | 1000 | 0.052 | TECR04100 | φ41 | 1000 | 2.84 |
TECR00800 | Φ8 | 1000 | 0.11 | TECR04200 | Φ42 | 1000 | 2.99 |
TECR01000 | Φ10 | 1000 | 0.17 | TECR04500 | φ45 | 1000 | 3.42 |
TECR01200 | Φ12 | 1000 | 0.25 | TECR05000 | φ50 | 1000 | 4.28 |
TECR01600 | φ16 | 1000 | 0.44 | TECR05300 | φ53 | 1000 | 4.75 |
TECR01670 | Φ16.7 | 1000 | 0.49 | TECR05500 | φ55 | 1000 | 5.12 |
TECR01748 | Φ17.48 | 1000 | 0.53 | TECR06000 | φ60 | 1000 | 6.10 |
TECR01800 | φ18 | 1000 | 0.55 | TECR06350 | Φ63.5 | 1000 | 6.97 |
TECR02000 | φ20 | 1000 | 0.69 | TECR06800 | φ68 | 1000 | 7.96 |
TECR02200 | φ22 | 1000 | 0.83 | TECR07000 | φ70 | 1000 | 8.44 |
TECR02400 | φ24 | 1000 | 0.99 | TECR07620 | Φ76.2 | 1000 | 10.15 |
TECR02500 | φ25 | 1000 | 1.07 | TECR08000 | φ80 | 1000 | 10.90 |
TECR02600 | φ26 | 1000 | 1.14 | TECR09000 | φ90 | 1000 | 14.24 |
TECR02800 | φ28 | 1000 | 1.47 | TECR11000 | φ110 | 1000 | 21.36 |
TECR03000 | φ30 | 1000 | 1.53 | TECR12000 | Φ120 | 1000 | 24.87 |
TECR03200 | φ32 | 1000 | 1.76 | TECR13000 | Φ130 | 1000 | 29.65 |
TECR03400 | φ34 | 1000 | 1.97 |
Packing and Shipping of Customizable Thickness fiberglass rods that conforms to IEC61109 Standard:
Packaging and Shipping for Insulator Fittings
Insulator fittings must be carefully packaged and shipped to ensure their safe arrival. Here are the steps to packaging and shipping insulator fittings:
Step 1: Clean and Inspect the Fittings
Before packaging and shipping the insulator fittings, it is important to clean the parts and inspect them for any damage or defects. This will help ensure that the fittings are in good condition and will not be damaged during the shipping process.
Step 2: Package the Fittings
Once the fittings have been cleaned and inspected, they should be carefully packaged using bubble wrap or other suitable material. The package should be securely sealed with tape to prevent damage during shipping. If multiple fittings are being shipped, they should be separated and packaged to prevent damage.
Step 3: Label the Package
Before shipping, the package should be clearly labeled with the correct address and contact information. This will help ensure that the package is delivered to the correct location. It is also important to include any other relevant information such as product name, quantity, weight, and any special instructions.
Step 4: Ship the Package
Once the package is labeled and sealed, it can be shipped using a reliable courier service. The courier service should provide tracking information so that the package can be monitored and tracked during transit.
.